空间广告
在线情况
楼主
  • 头像
  • 级别
    • 积分12
    • 经验49
    • 文章10
    • 注册2012-11-26
    Fabrication of a peristaltic micro pump with novel cascaded actuators
    Fabrication of a peristaltic micro pump with novel cascaded actuators [P][/P]Fabrication of a peristaltic micro pump with novel cascaded actuators [P][/P][P][/P]This paper presents the fabrication of an all-PDMS (polydimethylsiloxane) [URL=http://www.dhk.com.tw/]micro pump[/URL] with novel cascaded actuators as dynamic valves. The micro pump consists of three pneumatic actuators in series and a micro fluidic channel connecting two fluidic inlet and outlet ports. The three-layer bonded pump structure is fabricated through a typical moulding process of PDMS and a simple heating process for the PDMS-to-PDMS bonding. The total size of the micro pump is 5 mm × 5 mm. The dynamic valve pattern of the single actuator is observed under various operational conditions of the square-wave input signal for the estimation of its volume stroke. The maximum volume stroke of the pneumatic actuator for liquid is about 85% of the volume of the liquid chamber. [URL=http://www.dhk.com.tw/]Three types of liquid-pumping tests are performed for characterization of the micro pump such as backpressure, frequency and viscous liquids[/URL]. The flow rate of the de-ionized (DI) water is about 73.9 nl min?1 at zero backpressure. As the hydraulic difference between inlet and outlet ports increases, the flow rate gradually decreases. In the case of the frequency responses, the micro pump has the maximum flow rate of the DI water at 2 Hz. The viscosity-dependent flow rate of the working fluids is also observed. [P][/P][P][/P]The authors propose a new prototype model of a micro pump using an ICPF (ionic conducting polymer film) actuator as the servo actuator. This micro pump consists of two one-way valves that make use of the same ICPF actuator. The overall size of this micro pump prototype is 12 mm in diameter and 20 mm in length. The actuating mechanism is as follows. (1) The ICPF actuator used as the diaphragm is bent into the anode side by application of electricity. Then the volume of the pump chamber increases, resulting in the inflow of liquid from the inlet to the chamber. (2) By changing the current direction, the volume of the pump chamber decreases, resulting in liquid flow from the chamber to the outlet. (3) When the ICPF actuator is given a sinusoidal voltage, the micro pump provides liquid flow from the inlet to the outlet continuously. The characteristics of the micro pump have been measured. The experimental results indicate that the micro pump has satisfactory responses. [P][/P][URL=http://www.dhk.com.tw/]http://www.dhk.com.tw/[/URL]
    [ 此帖最后由Karlson在2012-12-4 20:52:00从 使用指南 转移过来 ]
    风之帝国感谢您的参与
    loading...
    loading...
    loading...
    loading...
    loading...
    loading...
    loading...
    回复帖子 注意: *为必填项
    *验证信息 用户名 密码 注册新用户
    *帖子名称
    内容(最大50K)




    其它选项 Alt+S快速提交
     


    Powered by LeadBBS 9.1 licence.
    Page created in 0.0781 seconds with 2 queries.